[. . . ] www. sylvania. com QUICKTRONIC® T8 Instant Start 347 Volt ­ Canada Normal, Low & High Ballast Factor Standard & Professional Series Lamp / Ballast Guide 32W T8 - OCTRON 1-lamp QTP1x32T8/347 ISN-SC 2-lamp QTP2x32T8/347 ISN-SC 3-lamp QTP3x32T8/347 ISN-SC 4-lamp QTP4x32T8/347 ISN-SC ® SYLVANIA QUICKTRONIC 32IS-SC operates OCTRON T8 lamps with maximum efficacy and provides 30-40% energy savings when compared to F40T12 magnetic systems. [. . . ] Insulate to 600 volts. FO96T8/XP QT2x59 IS FO96T8/XP/SS QT2x59 IS QUICKTRONIC 2x59 SPECIFICATION DATA Catalog # Project Comments Date Prepared by Type Normal, Low, High BF T8 Instant Start 347V Standard & Professional Performance Guide Data shown based upon SYLVANIA OCTRON® FO32/XP® & FO96 T8 XP Lamp(s). QUICKTRONIC® ballasts are also compatible with other lamp manufacturers' equivalent lamp types that meet ANSI specifications. Input Power (W) System Efficacy (lm/W) BEF1 Electronic T8 Fluorescent Systems 347V Item Number OSRAM SYLVANIA Description Input Current (AMPS) Lamp Type Rated Lumens (lm) No. of Lamps Ballast Factor System (BF) Lumens Mean Lumens QUICKTRONIC® Low Ballast Factor (0. 77) <20% THD 49241 49939 QT2x32T8/347 ISL-SC QT4x32T8/347 ISL-SC 0. 15 0. 28 FO32/XP FO32/XP 3000 3000 2 4 0. 77 0. 77 4620 9240 4345 8685 51 98 91 94 1. 51 0. 79 QUICKTRONIC® PROFESSIONAL Normal Ballast Factor (0. 88) <10% THD 49711 49713 QTP1x32T8/347 ISN-SC QTP2x32T8/347 ISN-SC 0. 089 0. 165 0. 25 0. 33 FO32/XP FO32/XP FO32/XP FO32/XP 3000 3000 3000 3000 1 2 3 4 0. 88 0. 88 0. 88 0. 88 2640 5280 7920 10, 560 2480 4965 7445 9925 31 59 86 112 90 89 92 94 2. 84 1. 49 1. 02 0. 78 Specifications Starting Method: Instant Start Ballast Factor: 0. 77, 0. 88 & 1. 20 Circuit Type: Parallel Lamp Frequency: All SC models >40kHz Standard enclosure >20kHz Lamp CCF: Less than 1. 7 Starting Temp:3 QTP models: -20°F (-29°C) for OCTRON T8 lamps QT models: 0°F (-18°C) for OCTRON T8 lamps 60°F (16°C) for SUPERSAVER® T8 lamps 0°F (-18°C) for FO40T8 Input Frequency: 60 Hz THD: QTP <10%, QT <20% Power Factor: >97% Voltage Range: ±10% of Rated Input UL Listed Class P, Type 1 Outdoor CSA Certified 70°C Max Case Temperature FCC 47 CFR Part 18 Non-Consumer Class A Sound Rating ANSI 62. 41 Cat. A Transient Protection GFCI compatible Emergency ballast compatible Remote Mounting (Max. wire length from ballast case to lampholder): · 20 ft: full wattage T8s · 10 ft: energy saving T8s · 4 ft: 25W energy saving T8s 3 Operation below 50°F (10°C) may affect light output or lamp operation ­ see "Low Temp. Starting" definition. NEW! 49715 QTP3x32T8/347 ISN-SC 49716 Pallet Pack 49717 QTP4x32T8/347 ISN-SC 49718 Pallet Pack QUICKTRONIC® High Ballast Factor (1. 20) <20% THD 49927 QT2x32T8/347 ISH-SC 2 0. 23 FO32/XP 3000 2 1. 2 7200 6770 78 92 1. 54 QUICKTRONIC 59T8 (8 Foot) Normal Ballast Factor (0. 88) <20% THD 49217 QT2x59/347 IS 0. 33 FO96T8 XP(59W) 6100 2 0. 88 10, 735 10, 090 110 98 0. 80 Products above are 10-pack unless noted. Pallet Pack contains 840 pieces, (add "-PAL" to Description). 1: Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power. [. . . ] (approx. ) 8. 70 mm Slot Width 49713 QTP 2 x 32T8 / 347 ISN - SC Case Size Starting/Ballast Factor Line Voltage Primary Lamp Wattage Specifications subject to change without notice. [. . . ]